FDA Logo U.S. Food and Drug AdministrationCenter for Food Safety and Applied Nutrition
U.S. Department of Health and Human Services

June 2, 2005

Milk Safety References
National Conference on Interstate Milk Shipments (NCIMS)

ELECTRONIC SOMATIC CELL COUNT
Foss 90
[Unless otherwise stated all tolerances are ±5%]

  1. __________ Laboratory Requirements (see CP, item 33 & 34)
    1. __________ Un-preserved samples may be run from 24 to 72 hours after initial collection
    2. __________ Samples may be run from 8 hours up to 7 days after initial collection if preserved with 0.02% 2-bromo- 2-nitropropane-1,3-diol (BronopolTM)or 0.05% potassium dichromate (K2Cr2O7)
    3. __________ Comparative test with DMSCC
      1. __________ Performed by each analyst performing ESCC test
      2. __________ Test 4 samples (100K-200K, 300K-500K, 600K-800K and 900K-1.2M) in triplicate for both DMSCC (three separate smears each) and ESCC (three separate sub-samples each, do not read same sample three times)
      3. __________ Results must be shown to be acceptable prior to official testing by analyst performing comparison, i.e. analyst is not certified until found acceptable. (co-requisite for certification)
      4. __________ Copy of comparison and results in QC record (or easily accessible file in laboratory)
    4. __________ Analysts certified in DMSCC

      APPARATUS

  2. __________ See Cultural Procedures, items 1–5
  3. __________ Fossmatic 90 Electronic Somatic Cell Counter
  4. __________ Pipettor, fixed volume or electronic (______________________)
    1. __________ Calibrated to deliver 500 µL milk (see CP item 6e)
    2. __________ Records maintained
  5. __________ Pipettor Tips
    1. __________ Disposable, replace for each sample
    2. __________ Reusable
      1. __________ Rinse in 40C deionized (DI) or MS water
      2. __________ Rinse in sample more than 1 time
      3. __________ Do not use for more than 25 samples
  6. __________ Water Bath
    1. __________ Circulating and thermostatically controlled to 37–42C

    REAGENTS

  7. __________ Stock Dye Solution, 0.1% Ethidium Bromide (caution TOXIC, use gloves when handling and do not breath dust)
    1. __________ Dissolve 1.0g ethidium bromide (C21H20BrN3) in 1 liter DI or MS water by heating to 40-60C
    2. __________ Store in light-proof, air-tight bottle no more than 60 days
    3. __________ Date prep. ________ Exp. Date ________
  8. __________All stock dye/buffer and detergent solutions labeled with date prepared and expiration date
    1. __________ Dissolve 10 mL Triton X-100 in 1 liter DI or MS water by heating to 60C.
    2. __________ Store in air-tight container no more than 25 days
    3. __________ Date prep. ________ Exp. Date ________
  9. __________ Dye/Buffer Solution
    1. __________ Dissolve 51.0g KH phthalate and 13.75g KOH in 10 L DI or MS water by heating to 40–60C
    2. __________ Add 150 mL 1% Triton X-100 (item 8), store less than 7 days in airtight container
    3. __________ Date prep. ________ Exp. Date ________
  10. __________ Ammonium Hydroxide (NH4OH) Solution, Reagent Grade, 25%
  11. __________ All stock dye/buffer/rinsing solutions labeled with date prepared and expiration date

    WORKING SOLUTIONS

  12. __________ Working Dye Solution/Zero Control (used within 7 days)
    1. __________ Dilute 26 mL stock dye solution (item 7a) to 2.5 liter with stock buffer solution (item 9b2)
    2. __________ Date prep. ________ Exp. Date ________
  13. __________ Cell Counter
    1. __________ Add 10 mL stock rinsing solution (item 8) to 25 mL of 25% NH4OH and dilute to 10 liters with DI or MS water
    2. __________ Date prep. ________ Exp. Date ________
  14. __________ Optionally use manufacturer's reagent kits and instructions specific for each instrument

    START UP

  15. __________ All working dye and rinsing solutions labeled with date prepared and expiration date
  16. __________ Cell Counter
    1. __________ Assure adequate volume of working solutions, not used beyond expiration date(s)
    2. __________ Turn on power and cycle at least six times__________
    3. Blind count
    4. __________ Vacuum pressure setting minimum of -40 KPa
    5. __________ Dispenser filling time 4–5 seconds
    6. __________ Intake filling time 3–4 seconds
    7. __________ IF ANY ABOVE PARAMETERS ARE WRONG, CORRECT BEFORE PROCEEDING
    8. __________ Records maintained on all parameters
  17. __________ Milk Standards
    1. __________ Commercially prepared: ____________________
      Lot# ______ Date Rcd. ______
      1. __________ Four samples in ranges 100K–200K, 300K–500K, 600K– 800K and 900K–1.2M
      2. __________ Do DMSCC in triplicate on each standard in set and average counts, records maintained
      3. __________ DMSCC check performed in rotation by all certified analysts
      4. __________ Standards used within one week
    2. __________ Certified provider: ___________________
      1. __________ Four standards in ranges 100K–200K, 300K-500K, 600K– 800K and 900K–1.2M
      2. __________ Maintain copies of all provided DMSCC values
      3. __________ Measure and maintain records of temperature (0–7.2C) of standards as received
      4. __________ Maintain copies of all correspondence regarding problems
      5. __________ Standards used by manufacturer's expiration date
      __________
    3. Laboratory prepared (weekly)
      1. __________ Prepare from raw milk > 18 hours old preserved with 0.05% potassium dichromate (K2Cr2O7)
      2. __________ Or, preserved with 0.02% 2–brono-2–nitropropane- 1,3–diol (Bronopol™)
      3. __________ Standards cannot be preserved with formalin
      4. __________ Prepare 4 standards in ranges 100K–200K, 300K–500K, 600K–800K and 900K–1.2M, used within one week
        Date prep. ________ Exp. Date ________
      5. __________ Do DMSCC in triplicate on each standard prepared and average counts, records maintained
      6. __________ DMSCC check performed in rotation by all certified analysts
    4. __________ Hourly Control Sample (instrument drift check)
      1. __________ Use one of the standards (items 17a or b) in the 500–800K range, run in triplicate and determine average
      2. __________ Optionally, prepare sufficient control/sample 500–800K range, run in triplicate and determine average

    PROCEDURE

  18. __________ Testing Standards (each time instrument used)
    1. __________ Heat standards to 37–42C (using a temperature control) and read within 30 minutes of reaching temperature, used once and then discarded, i.e., do not re-use
    2. __________ Invert 10 times, pipet 500 µL into intake chamber within 3 min
    3. __________ Run standards in triplicate and average the counts for each level, records maintained
    4. __________ Each standard's average must be within 10% of the DMSCC (item 17) for that level, except within 15% for 100–200K standard, records maintained
    5. __________ Repeatability – a standard in the 300K to 800K range must have a coefficient of variation (CV) of 5% or less on 10 replicates (Refer to Operating Manual), records maintained
    6. __________ THESE PARAMETERS MUST BE ACHIEVED BEFORE PROCEEDING__________
  19. Testing Samples
    1. __________ Heat samples to 37–42C (using a temperature control) and read within 30 minutes of reaching temperature, samples must not be re-used and must be discarded after use
    2. __________ Invert 10 times, pipet 500 µL into intake chamber within 3 min
    3. __________Record number of cells counted for each sample
  20. __________ With continuous operation:
    1. __________ Run a standard or optionally a control/sample (item 17d) in the 500K to 800K range hourly, must be within 5% of the original established instrument average value (optionally, within 10% of original DMSCC average)
    2. __________ Run standard/control 3x
    3. __________ Run zero control (in item 12)
    4. __________ Maintain records
  21. __________ Routine maintenance
    1. __________ Perform as described in operating manual
    2. __________ Maintain records

    REPORTS

  22. __________ Computing and Reporting Counts
    1. __________ Count obtained x 1000 is the cell count/mL milk
    2. __________ In reporting electronic somatic cell counts (ESCC/mL), record only first two left hand digits, raising second digit to next higher number when third digit is 6 or more
    3. __________ Report the two left hand digits (rounded)
      1. __________ If the third digit is 5 the second digit is rounded by the following rule
        1. __________ When the second digit is odd round up, raise the second digit by 1 (odd up, 235 to 240)
        2. __________ When the second digit is even round down, delete the 5 and report the second digit as is (even down, 225 to 220)
    4. __________ If count on instrument is < 100 report as < 100,000 ESCC/mL
horizontal rule
horizontal rule