| TO: | All Regional Food and Drug Directors Attn: Regional Milk Specialists |
| FROM: | Milk Safety Branch (HFS-626) |
| SUBJECT: | Honeywell DR4500A Truline Series HTST, STLR and Pasteurization Flow Circular Chart Recorder/Controller |
The Honeywell DR4500A Truline HTST, STLR and Pasteurization Flow Circular Chart Recorder/Controller has been reviewed and found to comply with the applicable provisions of the Grade "A" Pasteurized Milk Ordinance (PMO) when used both as a Pasteurization and Flow Recorder/Controller.
Compliance with the PMO is based upon construction, installation and operation, as described in the Manufacturer's Manual, (Doc No. 44-45-25-30) DR 4500A Truline Circular Chart Recorder Product Manual and Addendum (#44-45-99-08), revised on 3/2004 and the following provisions:
The technical information that was reviewed constitutes the Honeywell DR4500A Truline Series HTST, STLR and Pasteurization Flow Circular Chart Recorder/Controller Engineering Design Technical and Construction file (EDTCF).
For additional information regarding this equipment, please contact:
Douglas Bradway, P.E.
Honeywell Sensing and Control
1100 Virginia Drive
Fort Washington, PA 19034
Phone: (215) 641-3001
Fax: (215) 641-3599
E-mail:
FDA's review and acceptance of this piece of equipment does not constitute FDA endorsement or approval of this equipment. Any representation on a label or in printed literature citing or indicating as "FDA Approved" is false and misleading.
Copies of this memorandum are enclosed for distribution to Regional Milk Specialists, State Milk Regulatory Agencies and State Milk Sanitation Rating Officers in your region. This memorandum should be widely distributed to representatives of the dairy industry and other interested parties and will also be available on the FDA Web Site at http://www.cfsan.fda.gov at a later date.
If you would like an electronic version of this document prior to it being available on the CFSAN Web Site, please e-mail your request to .
/ss/
Jonathan M. Gardner
FDA/MSB Milk Sanitation Officer
Attachments:
Equipment Literature
Locking and Sealing Procedures
Sealing Procedures
Configuration Values
Honeywell DR4500A Truline Circular Chart Recorder
Honeywell DR4500A Truline Circular Chart Recorder