TO: All Regional Food and Drug Directors
Attn: Regional Milk Specialists
FROM: Milk Safety Branch (HFS-626)
SUBJECT: Sudmo D620-PMO Series Single-Bodied Double Seat Valve (1", 1.1/2, 2",
2 1/2", 3", 4", and 6")
The Sudmo D620-PMO Series Single-Bodied Double Seat Valve (1", 1.1/2, 2", 2 1/2",
3", 4", and 6") has been reviewed and found to comply with the applicable
provisions of the Grade "A" Pasteurized Milk Ordinance (PMO) when used to
separate cleaning product solution and milk and milk products.
Compliance with the PMO is based upon construction, installation, and operation
as described in the manufacturer's manual and attachments.
The Sudmo D620-PMO Series Singled-Bodied Double Seat Valve as a component is
designed to comply with Item 15p. PROTECTION FROM CONTAMINATION, 15p(B) of the
PMO. The valve may be used as part of a fail-safe system to separate milk and
milk product from tanks or circuits containing cleaning and/or sanitizing
solution.
The technical information that was reviewed, addressing the Sudmo D620-PMO
Series Singled-Bodied Double Seat Valve, constitutes Sudmo's Engineering Design
and Technical Construction File.
For further information contact:
Jim McCoy
Sudmo Inc.
6918 Forest Hills Road
Rockford, IL 61111
Phone: (815)-639-0322
Fax: (185)-639-1135
FDA's review and acceptance of this Single-Bodied Double Seat Valve does not
constitute agency endorsement or approval. Any representation on a label or in
printed literature citing or indicating "FDA Approved" is false and misleading.
Copies of this memorandum are enclosed for distribution to Regional Milk
Specialists, State Milk Regulatory Agencies and State Milk Sanitation Rating
Officers in your region. This memorandum will also be available on the FDA Web
site at http://www.cfsan.fda.gov at a later date and should be widely
distributed to representatives of the dairy industry and other interested
parties.
Jonathan M. Gardner
Sr. Milk Sanitation Officer
Attachments:
Literature/Technical Information (pages 3-5)
Proximity Switch Adjustment Procedure (page 6)
Regulatory Test Procedures (pages 7-8)