U. S. Food and Drug Administration
Center for Food Safety and Applied Nutrition
FDA Prime Connection


M-b-321 - G &H PD340 MBTS Magnetic Flow Meter, etc. (6/30/95)
 
 
HHS:PHS:FDA:CFSAN:OFP:DCP:MSB
 
                                          200 C Street, S.W.
                                          Washington,  DC  20204
 
                                          M-b-321
 
                                          June 30, 1995
 
 
TO:         All Regional Food and Drug Directors
            Attn:  Regional Milk Specialists
 
FROM:       Milk Safety Branch  (HFS-626)
 
SUBJECT:    G & H PD340 MBTS Magnetic Flow Meter
            G & H Products Corp., Kenosha, WI
 
 
 
The PD340 MBTS Magnetic Flow Meter has been reviewed as a stand
alone unit and found to comply with the intent of the applicable
provisions of the Grade A Pasteurized Milk Ordinance (PMO) for
HTST milk pasteurizing systems when installed and operated with
manufacturers operating instructions and the following
provisions:
 
      1.    The flow meter shall be installed in compliance with
            the criteria for COMPONENTS and PLACEMENT OF
            COMPONENTS detailed in Appendix H., Magnetic Flow
            Meter Based Timing Systems for HTST Pasteurizers,
            Grade A Pasteurized Milk Ordinance.
 
      2.    The flow meter is programmed at the factory and has
            a lock switch inside the cover.  The flow meter
            converter shall have restricted access to protect
            the programmed conversion factors.  It will come
            with temporary seals from the manufacturer.  On
            installation, the regulatory agency shall seal by
            the application of seals through the drilled cover
            bolts that are provided.
 
      3.    The eight preset registers shall be verified by the
            regulatory agency upon installation and when
            regulatory seals have been broken in accordance with
            G & H PD340 MBTS instructions.  It will be necessary
            for the user to provide access to G & H PD210
            display unit for use by the regulatory agency.
 
      4.    When installed, the flow meter shall comply with all
            test requirements (2A - 2F) of test 11, PMO, for
            Magnetic Flow Meters.
 
 
Copies of this memoranda are provided for distribution to state
milk control agencies and state milk sanitation rating officer
in your region.  States desiring further information or copies
of the materials concerning this equipment may contact:
 
                  G & H Products Corp.
                  7600 57th Avenue
                  P.O. Box 1199
                  Kenosha, WI  53141-1199
                  (800) 558-4060
                  Fax (414) 694-2907
                  Attn:  Per Anderson
 
FDA's review of this dairy equipment and our findings that it is
in compliance with the applicable items of the PMO does not
constitute agency endorsement or approval and any representation
on the label or in any printed literature that it is "FDA
Approved" is false.
 
 
 
 
                              Steven T. Sims
 
Attachments (2)
1. Instructions PD340 MBTS
2. PD340 MBTS for Meter Based Timing Systems

Go back to listing of M-B memos
Return to FDA Prime Connection Milk Safety references
Go BACK to CFSAN/FDA food and consumer information pages
Hypertext updated by ear, 11/19/96